SCOP and heat dissipation
according to EN14825
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Customer data:
|
|
|
|
|
|
|
|
|
|
|
| |
Select area - drop down menu
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Annual heating demand
|
|
kWh
|
|
|
|
|
|
|
|
|
| |
Percentage as base load
|
|
%
|
|
|
|
|
|
|
|
|
| |
Heat power base load
|
|
kW
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Heat pump data:
|
kW heat
|
COP
|
|
|
|
|
|
|
|
|
| |
At -7 outside temperature
|
|
|
|
|
|
|
|
|
|
|
| |
At 2 outside temperature
|
|
|
|
|
|
|
|
|
|
|
| |
At 7 outside temperature
|
|
|
|
|
|
|
|
|
|
|
| |
At 12 outside temperature
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Scaling heat pump size
|
|
%
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Results heat data:
|
|
|
|
|
|
|
|
|
|
|
| |
Heat demand
|
|
kWh
|
|
|
|
|
|
|
|
|
| |
Heat pump covers
|
|
kWh
|
|
|
|
|
|
|
|
|
| |
Heat pump covers
|
|
%
|
|
|
|
|
|
|
|
|
| |
Heat pump electricity consumption
|
|
kWh
|
|
|
|
|
|
|
|
|
| |
Backup consumption
|
|
kWh
|
|
|
|
|
|
|
|
|
| |
SCOPE
|
|
|
|
Investment:
|
|
|
|
|
| |
|
|
|
|
Flow temp.
level 60, 70 or 90
|
|
C
|
|
| |
Economy calculation:
|
|
|
|
Key figure
price 60 degrees system
|
|
Euro/kW ( std. 773 )
|
|
| |
Existing heating price
|
|
Euro/MWh
|
|
Key figure
price 70 degrees system
|
|
Euro/kW ( std. 920 )
|
|
| |
Back up heating price
|
|
Euro/MWh
|
|
Key figure
price 90 degree system
|
|
Euro/kW ( std. 1066 )
|
|
| |
Electricity price
|
|
Euro/MWh
|
|
Annual service
price
|
|
Euro/kW
|
|
| |
Saved existing heat
|
|
Euro.
|
|
Investment heat pump system
|
|
Euro.
|
|
| |
Consumption backup heat
|
|
Euro.
|
|
Service price per year
|
|
Euro/year
|
|
| |
Electricity consumption
|
|
Euro.
|
|
Return of investment
|
|
%
|
|
| |
Annual savings
|
|
Euro.
|
|
Present value over 10 years
|
|
Euro
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Basic data for standard heat pump: (can be copied
into heat pump data)
|
|
|
| |
* Data given includes brine pump and fan
consumption for air coolers. COP data are minimum values for estimating
potential.
|
|
|
| |
Flow temperature
|
60
|
60
|
60
|
|
|
|
|
| |
Return temperature
|
30
|
40
|
50
|
|
|
|
|
| |
|
kW heat
|
COP
|
kW heat
|
COP
|
kW heat
|
COP
|
|
|
|
|
| |
At -7 outside temperature
|
661
|
2,26
|
627
|
2,14
|
588
|
2,01
|
|
|
|
|
| |
At 2 outside temperature
|
815
|
2,78
|
770
|
2,63
|
719
|
2,45
|
|
|
|
|
| |
At 7 outside temperature
|
923
|
3,14
|
871
|
2,96
|
811
|
2,75
|
|
|
|
|
| |
At 12 outside temperature
|
1.051
|
3,54
|
987
|
3,32
|
920
|
3,09
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Flow temperature
|
70
|
70
|
70
|
70
|
|
|
| |
Return temperature
|
30
|
40
|
50
|
60
|
|
|
| |
|
kW heat
|
COP
|
kW heat
|
COP
|
kW heat
|
COP
|
kW varme
|
COP
|
|
|
| |
At -7 outside temperature
|
1.423
|
2,50
|
1.347
|
2,39
|
1.270
|
2,27
|
1.195
|
2,13
|
|
|
| |
At 2 outside temperature
|
1.739
|
2,86
|
1.640
|
2,75
|
1.536
|
2,62
|
1.432
|
2,46
|
|
|
| |
At 7 outside temperature
|
1.940
|
3,08
|
1.825
|
2,97
|
1.705
|
2,84
|
1.583
|
2,67
|
|
|
| |
At 12 outside temperature
|
2.194
|
3,29
|
2.061
|
3,19
|
1.923
|
3,06
|
1.780
|
2,89
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Flow temperature
|
80
|
80
|
80
|
80
|
|
|
| |
Return temperature
|
40
|
50
|
60
|
70
|
|
|
| |
|
kW heat
|
COP
|
kW heat
|
COP
|
kW heat
|
COP
|
kW varme
|
COP
|
|
|
| |
At -7 outside temperature
|
804
|
2,23
|
748
|
2,17
|
691
|
2,11
|
631
|
2,04
|
|
|
| |
At 2 outside temperature
|
956
|
2,45
|
890
|
2,39
|
821
|
2,32
|
750
|
2,24
|
|
|
| |
At 7 outside temperature
|
1.070
|
2,57
|
996
|
2,51
|
919
|
2,44
|
840
|
2,35
|
|
|
| |
At 12 outside temperature
|
1.194
|
2,68
|
1.112
|
2,62
|
1.027
|
2,55
|
938
|
2,47
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
Flow temperature
|
90
|
90
|
90
|
90
|
|
|
| |
Return temperature
|
50
|
60
|
70
|
80
|
|
|
| |
|
kW heat
|
COP
|
kW heat
|
COP
|
kW heat
|
COP
|
kW varme
|
COP
|
|
|
| |
At -7 outside temperature
|
749
|
2,07
|
694
|
2,00
|
637
|
1,93
|
578
|
1,84
|
|
|
| |
At 2 outside temperature
|
891
|
2,28
|
825
|
2,21
|
757
|
2,13
|
686
|
2,03
|
|
|
| |
At 7 outside temperature
|
998
|
2,40
|
924
|
2,33
|
847
|
2,24
|
767
|
2,14
|
|
|
| |
At 12 outside temperature
|
1.115
|
2,52
|
1.032
|
2,44
|
946
|
2,36
|
857
|
2,26
|
|
|
| |
* Performance data can be optimized according to
heat pump version and equipment level and when several are connected in
series.
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|